Understanding
Relays
|
24 of 27
|
![](relimages/delt02sl.gif)
|
![](relimages/delt02sr.gif)
|
OPERATIONAL
CHECK WITH TESTLIGHT
Now start the second part of the test. Energize the relay (control side)
by supplying B+ to pin 1 and a ground to pin 3. A click should be heard.
With the relay still energized, supply B+ pin 2 of the load circuit.
The test light will be on. De-energize (remove B+) the control circuit
at pin 1; the test light at pin 4 should go off. A test light is preferred
because a test light will draw current through the switch.
![](relimages/testwithlight.gif)
CAUTION
Testing
relays with built in clamping diodes require a special procedure. These
relays are polarity sensitive; placing B+ to the wrong pin (backwards)
while performing a practical test will forward bias the diode and damage
the diode, thus destroying the protective quality of the diode.
|